Vincent, S. and Iyer, Y.M. and Devasahayam, M.
(1999)
Computer controlled SOC monitor for lead acid batteries.
Bulletin of Electrochemistry, 15 (9-10).
pp. 368-371.
Abstract
A computer controlled state of charge (SOC) monitor for lead acid (LA) batteries was developed.This instrument has been developed with a powerful software and hardware package to monitor the SOC of the battery through measuring its internal resistance by means of step current pulse technique. Experimental results along with system descriptions and schematic diagrams are presented in this paper,