Ambalavanan, S. and Devasahayam, M. and Venkatakrishnan, N. (1999) Comparative study on the utilisaton of active material in the cast and expanded lead alloy negative grid. Bulletin of Electrochemistry, 15 (9-10). pp. 350-352.

[img]
Preview
PDF - Published Version
Download (1535Kb) | Preview

Abstract

This paper compares the performance of negative plates made from cast and expanded Pb-Ca-Sn grid alloy at different rates of discharge (current density). It has been found that at very low rate of discharge the active material utilisation of expanded grid is more whereas at high discharge rates the active material utilisation is more in the case of cast grid.

Item Type: Article
Uncontrolled Keywords: Lead acid battery; negative grid; alloy