Martha, S.K. and Hariprakash, B. and Gaffoor, S.A. and Ambalavanan, S. and Shukla, A.K. (2005) Assembly and performance of hybrid-VRLA cells and batteries. Journal of Power Sources, 144 (2). pp. 560-567.
PDF
- Published Version
Restricted to Registered users only Download (728Kb) | Request a copy |
Abstract
Several commercial-grade hybrid-VRLA and AGM-VRLA cells and batteries have been assembled and tested under varying charge–discharge rates in a temperature range between 50 and −40 ◦C. Impedance studies on hybrid-VRLA and AGM-VRLA cells have been conducted to reflect on their resistive and capacitive values. A linear relationship is found to exist between logarithmic state-of-charge values and ohmic impedance of batteries. In general, hybrid-VRLA cells and batteries perform better than their AGM-VRLA counterpart. A field-performance study conducted on AGM-VRLA and hybrid-VRLA batteries for solar-lighting application also suggests the latter to be superior.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | VRLA batteries; Absorbent-glass-mat (AGM); Gelled electrolyte; Colloidal silica; Hybrid; Oxygen recombination |
Subjects: | Lead acid batteries Electrochemical Power Sources |